Temposonics Linear Transducers
EP & EL Series Profile-Style Economy Position Sensors
Model EP position sensor - Full Size Profile Housing
Stroke Length: 50 mm to 3000 mm (2 in. to 120 in.)

Model EL position sensor - Low Height Profile Housing
Stroke Length: 50 mm to 2500 mm (2 in. to 100 in.)

MTS Temposonics EP Profile-Style and EL Low-Profile Economy Linear Transducers are highly repeatable, absolute position sensors for linear measurement. Absolute measurement offers safety for machine and automation devices. With absolute output, position information is instantly available. Power-down situations do not require rehoming of the device.

Using the unique magnetostrictive principle, that MTS pioneered, the sensor precisely senses the position of an external magnet through the housing wall, to measure position with a high degree of resolution and accuracy. The Temposonics EP/EL sensor’s innovative design is a result of MTS’s experience in magnetostrictive technology combined with solid engineering, extremely rugged construction and modern electronics. The Temposonics EP/EL is a precise, durable and cost effective alternative to linear potentiometers. They offer all the advantages of a non-contact position sensor suitable for a wide range of machines and automation applications.

Features

  • Ideal Replacement for Linear Pots
  • Non-contacting Temposonics sensing technology
  • Economical pricing
  • High resolution and linearity
  • Proven reliability and ruggedness


SPECIFICATION SHEET (pdf format)

Specifications

  • Measured Variables: Displacement
  • Resolution:
    • Analog: Infinite
    • Digital: 1 / [gradient x crystal freq. (MHz) x circulations]; controller dependent

  • Non-Linearity: <±0.02% of full stroke (minimum ± 60 µm)
  • Repeatability: <±0.001% of full stroke
  • Outputs:
    • Voltage: 0 to 10 Vdc and 10 to 0 Vdc (controller input resistance RL > 5 kOhm)
    • Current: 4 to 20 mA or 20 to 4 mA (min/max load: 0/500 Ohm)
    • Start/Stop; RS-422 differential signal (Serial parameter upload available for: measuring range, offset, gradient, status, and manufacturer number)

  • Measuring Range: 2 to 60 in. or 50 to 1525 mm.
  • Operating Voltage: +24 Vdc nominal (+20%, -15%)
  • Power Consumption: 50 to 140 mA (output & stroke dependent)
  • Operating Temperature:
    • Head Electronics -40°F to 167°F
    • Sensing Element -40°F to 221°F

  • Sealing: IP65 if mating cable connector is correctly fitted
  • Update Frequency:
    • Voltage or Current: > 1.5 kHz
    • Start/Stop: Controller dependent

  • Warranty: 2 Years
MTS Temposonics Series EP & EL Position Sensor Ordering
To order, complete the code number below by selecting the options desired in each category. Then click the "submit" button.
The part number and price will be displayed on the next page.


E __ 0 __ __ __ __ __ D __ __ 1 __ __ __
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
1-2. Sensor Model
EP = E-Series Profile-Style Position Transducer
EL = E-Series Low-Profile Position Transducer

3. Magnet Style
0 = EP and EL Sensors do not have housing options magnet types included in the standard model number. Magnets must be purchased separately by part number on the E-Series Accessories page.

4-7. Stroke Length - Stroke range U = 002.0 to 120.0 in., M = 0050-3000mm
(must correspond to Stroke Unit of Measurement selected in Item 8)


8. Stroke Unit of Measurement ( choose U for inches and tenths or M for millimeters)
U = Inches and tenths (Encode in 1, 2 or 4 inch increments as indicated in chart below)
M = Millimeters (Encode in 25mm, 50mm or 100mm increments as indicated in chart below)
Stroke Length (inches)* Ordering Increment
Stroke Length (mm)* Ordering Increment
≤ 20 inches 1 inch
≤ 500mm 25mm
> 20 inches and ≤ 100 inches 2 inches
> 500mm and ≤ 2500 mm 50mm
> 100 inches and ≤ 120 inches 4 inches
> 2500mm and ≤ 3000mm 100mm
* The maximum stroke length for Analog Voltage and Current sensors is 100 inches or 2500mm.

9-11. Connector
D34 = 5-Pin (M12), male, (Analog output - current and voltage)
D84 = 8-Pin (M12), male, (Digital output - start/stop)

12. Input Voltage
1 = +24 Vdc (+20%, -15%)

13-15. Output Signal
Analog - Voltage
V01 = 0 to +10 Vdc (1 output channel with 1 magnet)
V11 = +10 to 0 Vdc (1 output channel with 1 magnet)
V02 = 0 to +10 Vdc (2 output channels with 2 magnets)
V12 = +10 to 0 Vdc (2 output channel2 with 2 magnets)
V03 = 0 to +10 Vdc and +10 to 0 Vdc (2 output channels with 1 magnet)
Analog - Current
A01 = 4 to 20 mA (1 output channel with 1 magnet)
A11 = 20 to 4 mA (1 output channel with 1 magnet)
A02 = 4 to 20 mA (2 output channels with 2 magnets)
A12 = 20 to 4 mA (2 output channels with 2 magnets)
Digital - Pulse
R3 = Start/Stop with sensor parameters upload function
Fully compatible with the Start/Stop output Option R0 used in the previous generation E-Series sensors.

Temposonics EP & EL Sensors are made-to-order and usually ship in 4-6 weeks, FOB: Culver City, CA.