Temposonics Linear Transducers
ER Series Rod & Cylinder-Style Economy Position Sensors
MTS Temposonics ER Rod & Cylinder-Style Economy Linear Transducers are highly repeatable, absolute position sensors for linear measurement. Absolute measurement offers safety for machine and automation devices. With absolute output, position information is instantly available. Power-down situations do not require rehoming of the device.

Using the unique magnetostrictive principle, that MTS pioneered, the sensor precisely senses the position of an internal magnet as the rod moves, to measure position with a high degree of resolution and accuracy. The Temposonics ER sensor’s innovative design is a result of MTS’s experience in magnetostrictive technology combined with solid engineering, extremely rugged construction and modern electronics. The Temposonics ER is a precise, durable and cost effective alternative to linear potentiometers. They offer all the advantages of a non-contact position sensor suitable for a wide range of machines and automation applications.

FEATURES

  • Ideal Replacement for Linear Pots
  • Non-contacting Temposonics sensing technology
  • Economical pricing
  • High resolution and linearity
  • Proven reliability and ruggedness
Specifications

  • Measured Variables: Displacement
  • Resolution:
    • Analog - Infinite
    • Start/Stop: 0.005mm

  • Non-Linearity: <±0.02% of full stroke
  • Repeatability: <±0.001% of full stroke
    Hysteresis: <0.004 mm
  • Outputs:
    • Voltage: 0 to +10 Vdc or +10 to 0 Vdc (controller input resistance RL > 5 kOhm)
    • Current: 4-20 mA or 20-4 mA (min/max load: 0/500 Ohm)
    • Start/Stop; RS-422 differential signal (Serial parameter upload available for: measuring range, offset, gradient, status, and manufacturer number)
      Start/Stop: RS-422 differential signal

  • Measuring Range: 2 to 60 in. or 50 to 1500 mm.
    • ER sensors standard stroke ranges are 3, 6, 9, 12, 15, 18, 21, 24, 30, 36, 42 48, 54 and 60 inches (75, 100, 150, 200, 300, 400, 500, 600, 750, 1000, 1250, 1500 mm). Custom stroke lengths available

  • Operating Voltage: +24 Vdc (+20%, -15%)
  • Power Consumption: 50 to 140 mA (output & stroke dependent)
  • Operating Temperature: -40°C to 75°C
  • Sensing Head & Housing: Aluminum

  • Rod: Stainless Steel Type 303
  • Sealing: IP67
  • Warranty: 2 Years

MTS Temposonics Series ER Position Sensor Ordering
To order, complete the code number below by selecting the options desired in each category. Then click the "submit" button.
The part number and price will be displayed on the next page.


E R __ __ __ __ __ __ D __ __ 1 __ __ __
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
1-2. Sensor Model
ER = E-Series Rod & Cylinder-Style Position Transducer

3. Type of Thread (choose S or M)
S = Inside thread 1/4-28 (English). Must be used for ER sensors having US stroke lengths ("U" in item 8).
M = Inside thread M6 (Metric). Must be used for ER sensors having Metric stroke lengths ("M" in item 8).

4-7. Stroke Length - Stroke range = 002.0 to 060.0 in. or 0050-1500mm
(must correspond to Stroke Unit of Measurement selected in Item 8)


8. Stroke Unit of Measurement (choose U for inches and tenths or M for millimeters)
U = Inches and tenths- Encode in 1 or 2 inch increments, for example: 0050U = 5.0 in, 0600U = 60.0 in
(Preferred stroke lengths are: 3, 6, 9, 12, 15, 18, 22, 24, 30, 42, 48 and 54 inches)
M = Millimeters (Encode in 25 or 50mm increments, for example: 0125M = 125 mm, 1200M = 1200 mm)
(Preferred stroke lengths are: 75, 100, 150, 200, 300, 400, 500, 600, 750, 1000 and 1250 mm)
Stroke Length (inches)* Ordering Increment
Stroke Length (mm)* Ordering Increment
≤ 20 inches 1 inch
≤ 500mm 25mm
> 20 inches and ≤ 60 inches 2 inches
> 500mm and ≤ 1500 mm 50mm

9-11. Connector
D34 = 5-Pin (M12), male, (Analog output - current and voltage)
D84 = 8-Pin (M12), male, (Digital output - start/stop)

12. Input Voltage
1 = +24 Vdc (+20%, -15%), standard

13-15. Output Signal (choose V01, V11, V03, A01, A11 or R3)
Analog - Voltage
V01 = 0 to +10 Vdc
V11 = +10 to 0 Vdc
V03 = 0 to +10 Vdc and +10 to 0 Vdc (2 output channels)
Analog - Current
A0 = 4 to 20 mA
A1 = 20 to 4 mA
Digital - Pulse
R3 = Start/Stop with sensor parameters upload function.
Fully compatible with the Start/Stop output Option R0 used in the previous generation E-Series sensors.

NOTE: Mounting feet for the Temposonics ER sensor must be ordered separately. Order 2 mounting feet, (Part No. 403508), for sensors up to 50 in. (1250mm). One additional mounting foot is recommended for longer lengths.
Temposonics ER Sensors are made-to-order and usually ship in 4-6 weeks, FOB: Culver City, CA.