Temposonics Linear Transducers
Temposonics G Series - Next Generation Position Sensors
For Upgrading from Obsolete Tempo II and L-Series Sensors
MTS Sensors, the inventors of magnetostrictive position sensing and makers of Temposonics sensors, is proud to introduce the new G-Series Linear Position Sensors utilizing their "next generation" technology platform. The new G-Series position sensors feature a microprocessor-based design with enhanced diagnostics and programmability. They are available in both Hydraulic Rod Style and Profile Style housing configurations.

Backwards compatibility is one of the primary benefits of the new G-Series position sensor. G-Series position sensors provide the same functionality as Tempo II and L-Series sensors, making them an ideal direct replacement for these products.

Advanced Communication and Programmability
By using external communication for monitoring and programming of the G-Series position sensor, there is no need to open the electronics housing. This simplifies installation and commissioning, saving valuable time. Keeping the sensor electronics isolated ensures that seal integrity and the highest product reliability are maintained.

The new platform technology inside the G-Series enables:
  • Infrared (IR) send and receive for wireless communication
  • Built-in serial interfaces for robust hard-wired serial communication (RS-422 for digital-pulse outputs and RS-485 for analog outputs)
  • Remote programmability for operational modes and sensor parameters
  • Enhanced monitoring and diagnostic capabilities

In addition to providing advanced programming and diagnostic capabilities in a rugged package, the G-Series position sensors also include the following features:

  • Electronics housing small enough to allow for drop in replacements of legacy Temposonics products
  • Standard 24Vdc and extended input power supply options for compatibility with older controller interfaces
  • Fully adjustable voltage and current outputs within:
    • -10 to +10 Vdc or +10 to -10 Vdc
    • 0 to 20 mA or 20 to 0 mA
  • Digital-pulse outputs: Start/Stop and PWM
  • All outputs available up to 300 in. stroke length (hydraulic-rod style)
  • Up to 15 magnet positions simultaneously using the Start/Stop output option
  • Integral connector replacement options including: hanging (inline) connectors, adapter cables, and field-installed connector kits.


SPECIFICATION SHEET

Enhanced Monitoring and Diagnostics
The G-Series simple visual user interface helps resolve the majority of customer installation and troubleshooting issues. Integrated LEDs (see image below) indicate:
  • Normal operating conditions
  • Error conditions, power and sensor/control interface issues
  • Programming modes (IR or hard wired)

Hard-wire G-Series serial communication enables diagnostic feedback at a convenient remote location. Access to internal sensor conditions minimizes troubleshooting efforts and enables the development of more sophisticated controller diagnostic routines. All of these features will simplify sensor installation and maximize operational productivity.

Specifications

  • Measured Variable: Displacement
  • Resolution:
    • Analog: Infinite
    • Digital: 1÷ [gradient x crystal freq. (mHz) x circulation]
  • Non-Linearity: <±0.02% of full stroke or ±0.002 in. (±0.05mm) whichever is greater.
  • Repeatability: ±0.001% of full stroke or ±0.0001 in. (±0.0025mm), whichever is greater.
  • Outputs:
    • Analog: Voltage or Current
    • Digital: Start/Stop or PWM
  • Measuring Range:
    • Profile Style:
      • Analog: 50 to 2540 mm (2 to 100 in.)
      • Digital: 50 to 5080 mm (2 to 200 in.)
    • Hydraulic Rod Style: 1 to 300 in. (25 to 7620 mm)
      • Analog: 50 to 2540 mm (2 to 100 in.)
      • Digital: 50 to 7620 mm (2 to 300 in.)
  • Operating Voltage:
    • +24 Vdc nominal (20.4 - 28.8 Vdc) standard
    • +9 to +23 Vdc optional
  • Operating Temperature: -40°F to 176°F (-40°C to 80°C)
  • EMC Test: Emissions IEC/EN 61000-6-3, Immunity IEC/EN 61000-6-2, IEC/EN 61000-4-2/3/4/5/6/8, level 3/4 criterium A, CE qualified
  • Shock Rating: 100 g (single hit)/IEC standard 68-2-27 (survivability)
  • Vibration Rating: 5 g/10-2000 Hz/IEC standard 68-2-6
  • Adjustability: Field adjustable null and span (analog sensors only)
  • Update Time:
    • Analog: < 1ms (typical)
    • Digital: Minimum = [2.5 + null + stroke (inches)] x 10.0 ms/in x [number of recirculations]
  • Warranty: 2 Years

PROFILE STYLE (GP Model)

  • Electronic Head: aluminum housing
  • Sealing: IP67
  • Sensor Extrusion: Aluminum (Temposonics profile style)
  • Mounting: Adjustable mounting fee or T-slot M5 nut in base channel
  • Magnet Type: Captive-sliding magnet or floating magnet

ROD STYLE (GH Model)

  • Electronic Head: aluminum housing
  • Sealing: IP67
  • Sensor Rod: 304L Stainless Steel
  • Operating Pressure: 350 bar (5,000psi) static, 690 bar (10,000 psi) spike
  • Mounting: Threaded flange M18 x 1.5 or 3/4-16 UNF-3A
  • Typical Mounting Torque: 45 N-m (33 ft.-lbs.)
  • Magnet Type: Ring or floating magnet
How to Order Temposonics G Series Transducers

When placing an order, build the desired model number using this model number guide (below).
Select the configuration in the ordering table and then hit the "Submit" button at the bottom of the page.

A selection of Temposonics G-Series sensor configurations are available to meet the demands of your particular application. If you have any questions about how to apply MTS Temposonics position sensors, please contact us at West Coast Plastics Equipment, 800-392-8569. We are an authorized MTS Temposonics distributor and will be glad to help you design an effective position sensing system to fit your application.

G __ __ __ __ __ __ __ __ __ __ __ __ __ __
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
1-2. Sensor Model Price
GH = Hydraulic Rod Style Sensor Stroke
Dependent
GP = Profile Style Sensor

3. Housing Style

Temposonics GH only (magnet must be ordered separately):
T = US customary threads, raised-face hex, and pressure tube N/C
S = US customary threads, flat-faced hex, and pressure tube N/C
M = Metric threads, flat-faced hex, and pressure tube N/C

Temposonics GP only (magnet included):
V = Captive Sliding Magnet with joint at front (#252184 magnet included) N/C
S = Captive Sliding Magnet with joint at top (#252182 magnet included) N/C
M = Floating Magnet (#251416-2 magnet included) N/C

4-7. Stroke Length - Stroke range = 002.0 to 300.0 in. or 0050-7620mm (must correspond to Stroke Unit of Measurement selected in Item 8)
GH Voltage or Current Stroke Range = 2-100 inches (50-2540mm)
GH Digital Pulse Stroke Range = 2-300 inches (50-7620mm)
GP Voltage or Current Stroke Range = 2-100 inches (50-2540mm)
GP Digital Pulse Stroke Range = 2-200 inches (50-5080mm)

8. Stroke Unit of Measurement ( choose U for inches and tenths or M for millimeters)
U = Inches and tenths (Encode in 0.1 inch increments, for example: 0125U = 12.5 in, 1200U = 120 in)
M = Millimeters (Encode in 5mm increments, for example: 0120M = 120 mm, 1200M = 1200 mm)

9-11. Connection Type
D60 = 6-pin DIN connector, integral, standard N/C
MS0 = 10-pin MS style, male (digital pulse output) $124.00
R05 = Integral cable 5-foot (2 meters if metric), PVC jacket with pigtail connection (call if longer cable needed) N/C
F05 = Integral cable 5-foot (2 meters if metric), PURC jacket with pigtail connection (call if longer cable needed) $28.00
RB1 = 1 foot integral cable, PVC jacket, with male in-line RB connector2 $57.00
RB2 = 5 foot integral cable, PVC jacket, with male in-line RB connector2 $66.00
FM1 = 1 foot integral cable, PUR1 jacket, with male in-line 10-pin MS connector3 $93.00
FM2 = 5 foot integral cable, PUR1 jacket, with male in-line 10-pin MS connector3 $112.00

12. Input Voltage
1 = +24 Vdc (+20%, -15%), standard N/C
2 = +9 to +28.8 Vdc4 $73.00

13-14. Output Signal (2 or 3 digit code depending on output selected)
Analog - Voltage
V0 = 0 to +10 Vdc N/C
V1 = +10 to 0 Vdc N/C
V2 = -10 to +10 Vdc N/C
V3 = +10 to -10 Vdc N/C
Analog - Current
A0 = 4 to 20 mA N/C
A1 = 20 to 4 mA N/C
A2 = 0 to 20 mA N/C
A3 = 20 to 0 mA N/C
Digital - Pulse
R0 = Start/Stop - If more than one magnet needed, enter the number of magnets in hexadecimal in item 15 below N/C
N0 = Start/Stop output wired for square wave neuter. - If more than one magnet needed, enter the number of magnets in hexadecimal in item 15 below N/C
DE = Pulse-Width Modulated (PWM) with External Interrogation.
Fill in the desired number of circulations in hexadecimal in item 15 below.
N/C
DI = Pulse-Width Modulated (PWM) with Internal Interrogation.
Fill in the desired number of circulations in hexadecimal in item 15 below.
N/C

15. Number of Magnets (for Output R0 or N0) or Number of Circulations (for Output DE or DI)

0 = 0 3 =3 6 = 6 9 = 9 C = 12 F = 15
1 = 1 4 = 4 7 = 7 A = 10 D = 13 G = 16
2 = 2 5 = 5 8 = 8 B = 11 E = 14 K = 20
N/C
NOTES:
1 Polyurethane jacketed cable for use where higher resistance to moisture, oil and other environmental conditions are required.
2 Wired for analog or digital pulse depending on output selected. For Tempo II and LH replacements and retrofits only.
3 Wired for analog or digital pulse depending on output selected. For LH replacements and retrofits only.
4 Selected when retrofitting sensors with ± 15 Vdc input voltages.
Temposonics G-Series Sensors are made-to-order and usually ship in 4-6 weeks, FOB: Culver City, CA.